Z-1592-05
Epidural Infusion Pumps sold under the following labels; a) Baxter 6060E Epidural Infusion Pump, product code...
Baxter Healthcare Corporation / initiated 2005-08-17 / Terminated / root cause: software
Baxter Healthcare Corp. began a recall of Epidural Infusion Pumps sold under the following labels; a) Baxter 6060E Epidural Infusion Pump, product code 2L9351, 2L9351P and 2L9351R; Manufactured by an... on . The reason FDA records is "Potential overinfusion in the Auto-Ramp mode with software versions 3.00 or higher". As of , the recall status on record is Terminated, and MDM tags the root cause as software.
Recall record
- Recall number
- Z-1592-05
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Baxter Healthcare Corporation
- Product
- Epidural Infusion Pumps sold under the following labels; a) Baxter 6060E Epidural Infusion Pump, product code 2L9351, 2L9351P and 2L9351R; Manufactured by an affiliate of Baxter Healthcare Corp., Deerfield, IL 60013 USA, made in Singapore b) Sabratek 6060 Epidural Pain Management Pump, product codes 606000-40E and 606000-40EL; Manufactured by Sabratek Corp., Skokie, IL 60076, which was purchased by Baxter Healthcare Corp., Deerfield, IL in January 2000.
- Product code
- FRN Pump, Infusion
- Reason for recall
- Potential overinfusion in the Auto-Ramp mode with software versions 3.00 or higher
- Root cause tag
- software
- FDA root cause
- Other
- Action
- Baxter sent the 8/17/05 Urgent Product Recall letter to all Baxter 6060E Infusion Pump customers to inform them of a software anomaly present in software versions 3.00 and higher, which allows the pump to overinfuse in the Auto-Ramp mode. The end users were also informed that these epidural pumps, identified by the yellow housing, can no longer be supported due to a lack of availability of spare parts and Baxter is unable to replace the software with an alternate version. As a result, Baxter requested the accounts to remove the pumps from service and return them to Baxter. The accounts were requested to call Baxter''s Medication Delivery Services at 1-800-843-7867 to arrange for the return of the units and replacement with 6060 Multi-Therapy Infusion Pumps.
- Distribution
- Nationwide including Puerto Rico, and intenationally to Canada, China, Belgium, Hong Kong and Saudi Arabia
- Product codes and lots
- product codes 2L9351, 2L9351P, 2L9351R, 606000-40E and 606000-40EL: all serial numbers