Z-0373-2013Class II
6.5mm x 40mm Noncannulated Screw Shank Subsequent Codes: KWP, KWQ, MNH, MNI
NuVasive Inc / initiated 2009-01-05 / Terminated / root cause: design
NuVasive Inc began a recall of 6.5mm x 40mm Noncannulated Screw Shank Subsequent Codes: KWP, KWQ, MNH, MNI on . FDA classified it as Class II and gives the reason as "The tulip portion of the screw assembly can disengage from the shank after implantation". As of , the recall status on record is Terminated, and MDM tags the root cause as design.
Recall record
- Recall number
- Z-0373-2013
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- NuVasive Inc
- Product
- 6.5mm x 40mm Noncannulated Screw Shank Subsequent Codes: KWP, KWQ, MNH, MNI
- Product code
- NKB Thoracolumbosacral Pedicle Screw System
- Reason for recall
- The tulip portion of the screw assembly can disengage from the shank after implantation.
- Root cause tag
- design
- FDA root cause
- Device Design
- Action
- Telephone communications to the sales representatives of surgeons actively using the Posted Pedicle Screw System were made on 01/05/2009. The calls were unscripted and requested that all inventory be forwarded to NuVasive's San Diego office for quarantine. Surgeons who were actively using the system were also contacted and notified of the situation. Follow-up communications were sent via mail on 01/19/2009 to all surgeons who participated in the Alpha release. The letter informed the customers of the problems identified. Customers were instructed that the recalling firm does not believe any further action is required and they were instructed to monitor the progress of their patients and notify NuVasive if any issues are detected. Customers with questions or concerns are instructed to contact the firm at (858) 909-1964.
- Quantity in commerce
- 240 units total
- Distribution
- Nationwide Distribution-including the states of OR, MO, FL, WI, CA, and NC.
- Product codes and lots
- Batch: JK2055, JK2142, JK2172, JK2174, JK2192, JK2212, JK2173.
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-0348-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0349-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0350-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0351-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0352-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0353-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0354-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0355-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0356-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0357-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0358-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0359-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0360-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0361-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0362-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0363-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0364-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0365-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0366-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0367-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0368-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0369-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0370-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0371-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0372-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0373-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0374-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0375-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0376-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0377-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0378-2013 | Class II | Terminated | Voluntary: Firm initiated |
FIRST ARTICLE / WEEKLY
What cleared, what was recalled, and what changed in the standards. One edition a week for the people who make medical devices.