Z-0378-2010

Zimmer Natural Nail System, Tibial Targeting Guide Handle, small, nonsterile, Zimmer, Warsaw, IN; REF...

Zimmer GmbH / initiated 2009-07-01 / Terminated

Zimmer Inc. began a recall of Zimmer Natural Nail System, Tibial Targeting Guide Handle, small, nonsterile, Zimmer, Warsaw, IN; REF 00-2490-005-00. The device is used to drill into the... on . The reason FDA records is "The guides may come apart during use, some guides may experience surface cracking, guide handles and modules may not target the femoral nail holes accurately and the instruments may not be able to be assemble together...". As of , the recall status on record is Terminated.

Recall record

Recall number
Z-0378-2010
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Zimmer GmbH
Product
Zimmer Natural Nail System, Tibial Targeting Guide Handle, small, nonsterile, Zimmer, Warsaw, IN; REF 00-2490-005-00. The device is used to drill into the proximal tibia or distal femur for placement of screws that stabilize the position of an intramedullary nail implant. The targeting guide instrumentation serves to assist the surgeon in precisely drilling into the bone and through holes that are located in the proximal and distal portion of the nail implant. After these holes are drilled, screws are placed into the holes to hold the implant in place in the bone.
Product code
HSB Rod, Fixation, Intramedullary And Accessories
Reason for recall
The guides may come apart during use, some guides may experience surface cracking, guide handles and modules may not target the femoral nail holes accurately and the instruments may not be able to be assemble together due to a change in the threading method used.
FDA root cause
Other
Action
On July 1, 2009, U.S. distributors were notified by e-mail to return two instruments. The recall was expanded with international accounts notified by e-mail on August 5, 2009, and U.S. accounts being notified by e-mail on August 6, 2009, to return 7 instruments. The scope of the recall was then expanded again to include 14 instruments and another letter dated September 14, 2009 to distributors and user accounts. The notifications described the affected products, problem, health risks and actions for consignees. Direct questions about the recall to Zimmer, Inc. by calling 1-800-613-6131.
Quantity in commerce
327 of total product
Distribution
Worldwide Distribution -- United States, France, Germany, Italy, Switzerland and United Kingdom.
Product codes and lots
Lots 61161115, 61170213, 61219945, 61256543, 61233590 and 61256542.