Endotec Prothesis Ankle, Titanium Alloy, Sterilized, BP Ankle System. BP Ankle System, F-P Type III Ankle...
Endotec, Inc. began a recall of Endotec Prothesis Ankle, Titanium Alloy, Sterilized, BP Ankle System. BP Ankle System, F-P Type III Ankle Bearing Component: 2x5mm F-P Type III Ankle Bearing... on . The reason FDA records is "Endotec is recalling B-P Hip, B-P Shoulder, and B-P Knee Replacement System devices due to sterility issues involving validation, process variations and test results". As of , the recall status on record is Terminated, and MDM tags the root cause as sterility.
Recall record
- Recall number
- Z-1625-2010
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Endotec, Inc.
- Product
- Endotec Prothesis Ankle, Titanium Alloy, Sterilized, BP Ankle System. BP Ankle System, F-P Type III Ankle Bearing Component: 2x5mm F-P Type III Ankle Bearing Catalog: 05-13-0532, 2x7mm F-P Type III Ankle Bearing Catalog: 05-13-0732, 8x3mm F-P Type III Ankle Bearing Catalog: 05-13-0533, 8x1mm F-P Type III Ankle Bearing Catalog: 05-13-0731. BP Ankle System, F-P Type III Tibial Ankle Component: Size 1 F-P Type III Tibial Component Catalog: 05-12-0031, Size 2 F-P Type III Tibial Component Catalog: 05-12-0032, Size 3 F-P Type III Tibial Component Catalog: 05-12-0033. BP Ankle System, F-P Type III Talar Component: Size 1 F-P Type III Talar Component Catalog: 05-01-0031, Size 2 F-P Type III Talar Component Catalog: 05-01-0032, Size 3 F-P Type III Talar Component Catalog: 05-01-0033.
- Product code
- JWH Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
- Reason for recall
- Endotec is recalling B-P Hip, B-P Shoulder, and B-P Knee Replacement System devices due to sterility issues involving validation, process variations and test results.
- Root cause tag
- sterility
- FDA root cause
- Other
- Action
- Recall Letters were sent to each distributor on 06/07/2009. Questions are directed to Endotec at (407) 822-0021.
- Quantity in commerce
- 50 Pieces
- Distribution
- Worldwide distribution -- US in OH, TX, CA, FL, NJ, TN; and International Distribution: Korea, Australia, Switzerland, The Netherlands, Spain. Domestic: OH, TX, CA, FL, NJ, TN.
- Product codes and lots
- Lot No: 05010031BNN376 05010032BNN376 05010033BNN376 05010033CNN376 05120031BNN376 05120032BNN377 05120033BNN376 05130532BNN377 05130732BNN377 05130533BNN376 05130731BNN376
FIRST ARTICLE / WEEKLY