Medical Device
Manufacturing
THE TRADE PAPER OF THE FACTORY FLOOR
Z-1105-2010

Bio-Prep Bone Preparation Kit with Merocel sponge for use in total hip arthroplasty. REF 206-730, Rx...

Stryker Corp. / initiated 2010-01-25 / Terminated / root cause: labeling and UDI

Stryker Instruments Div. of Stryker Corporation began a recall of Bio-Prep Bone Preparation Kit with Merocel sponge for use in total hip arthroplasty. REF 206-730, Rx, Sterile, Stryker Instruments Kalamazoo, MI. The femoral... on . The reason FDA records is "The firm did not have packaging validation to support the labeled shelf life. There is potential for a breach in sterility specific to the sterile packaged femoral sponge which may result in a non-sterile product". As of , the recall status on record is Terminated, and MDM tags the root cause as labeling and UDI.

Recall record

Recall number
Z-1105-2010
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Stryker Corp.
Product
Bio-Prep Bone Preparation Kit with Merocel sponge for use in total hip arthroplasty. REF 206-730, Rx, Sterile, Stryker Instruments Kalamazoo, MI. The femoral sponge is an absorbent that is used to dry the intramedullary canal prior to the application of bone cement. The suction effectively absorbs blood and fluid from the canal. It may provide swabbing/scrubbing action during suction.
Product code
GDY Gauze/Sponge, Internal, X-Ray Detectable
Reason for recall
The firm did not have packaging validation to support the labeled shelf life. There is potential for a breach in sterility specific to the sterile packaged femoral sponge which may result in a non-sterile product.
Root cause tag
labeling and UDI
FDA root cause
Other
Action
A "Medical Device Recall Notification" dated January 21, 2010 was issued to customers. The notification described the affected product, issue and actions to take. Consignees were asked to forward the notification to all their affected locations. Customers were instructed to immediately check inventory and quarantine any recalled product found. Consignees were instructed to destroy all product and report how much product was destroyed. For questions regarding this recall, please contact Stryker Instruments by calling 1-800-800-4236, ext. 4354
Quantity in commerce
9,274 all products.
Distribution
Worldwide Distribution -- United States, Canada, Mexico, Australia, Brazil, Switzerland, Japan, Netherlands, England, UK, Sweden, Hong Kong, Korea, Malaysia, Singapore, Argentina, Spain, and Italy.
Product codes and lots
04230CE2, 04257CE2, 04286CE2, 04310CE2, 04334CE2, 05004CE2, 05041CE2, 05109CE2, 05200012, 05222012, 05292012, 05346012, 06038012, 06128012, 06172012, 06241012, 06268012, 06313012, 06348012, 07022012, 07031012, 07053012, 07081012, 07106012, 07136012, 07177012, 07192012, 07219012, 07253012, 07276012, 07320012, 07341012, 08010012, 08043012, 08063012, 08095012, 08127012, 08162012, 08177012, 08203012, 08249012, 08296012, 08325012, 08351012, 09040012, 09075012, 09106012 and 09138012.