Medical Device
Manufacturing
THE TRADE PAPER OF THE FACTORY FLOOR
Z-0599-2011

Medefil Heparin I.V. Flush Syringe 100 units/mL; a polypropylene luer locking syringe containing Heparin Lock...

Medefil, Inc. / initiated 2010-11-01 / Terminated / root cause: manufacturing process

Medefil Incorporated began a recall of Medefil Heparin I.V. Flush Syringe 100 units/mL; a polypropylene luer locking syringe containing Heparin Lock Flush Solution, USP, a sterile non-pyrogenic... on . The reason FDA records is "The heparin lock flush solution was manufactured with contaminated Heparin Sodium USP Active Pharmaceutical Ingredient (API)". As of , the recall status on record is Terminated, and MDM tags the root cause as manufacturing process.

Recall record

Recall number
Z-0599-2011
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Medefil, Inc.
Product
Medefil Heparin I.V. Flush Syringe 100 units/mL; a polypropylene luer locking syringe containing Heparin Lock Flush Solution, USP, a sterile non-pyrogenic, isotonic injection; each mL in a Heparin I.V. Flush Syringe contains 100 units of heparin sodium derived from porcine intestinal mucosa and 9 mg of sodium chloride in water for injection; Medefil, Inc. Glendale Heights, IL 60139. The pre-filled syringes were packed as 60 syringes per dispenser box, 16 boxes per shipping carton in the following syringe configurations: a) NDC# 64253-333-33, catalog # MIH-3333: 3 mL fill in 12 mL syringe; b) NDC# 64253-333-35, catalog # MIH-3335: 5 mL fill in 12 mL syringe
Product code
NZW Heparin, Vascular Access Flush
Reason for recall
The heparin lock flush solution was manufactured with contaminated Heparin Sodium USP Active Pharmaceutical Ingredient (API).
Root cause tag
manufacturing process
FDA root cause
Material/Component Contamination
Action
Medefil faxed/emailed the direct accounts on 11/1/10, and sent the accounts a hard copy of the Urgent Product Recall letter, dated 11/1/2010, on 11/2/10. The accounts were informed of Medefil's recall of 18 lots of Heparin I.V. Flush Syringes produced from the active pharmaceutical ingredient (API) Heparin Sodium, USP, lot 1035-0780, that has been recalled by the manufacturer, Scientific Protein Laboratories, due to the presence of a contaminant, Oversulfated Chondroitin Sulfate. The accounts were instructed to stop use of the 18 lots of Heparin I.V. Flush Syringes immediately, place them under quarantine, and contact Medefil to arrange for the product to be returned. The accounts were requested to complete and return to Medefil the enclosed response form, indicating the quantity on hand of each recalled lot. Any questions were directed to Pradeep Aggarwal, President at 630-682-4600.
Quantity in commerce
1,996,500 syringes
Distribution
Nationwide Distribution --- including states of Arizona, California, Florida, Illinois, Ohio, Louisiana, Massachusetts, Michigan, Minnesota, New York, Texas, and Virginia.
Product codes and lots
a) catalog # MIH-3333: Lot H109298, exp. date 08/11; Lot H110152, exp. date 01/12; b) catalog # MIH-3335: Lot H109291, exp. date 08/11; Lot H109293, exp. date 08/11; Lot H109295, exp. date 08/11; Lot H109297, exp. date 08/11; H109299, exp. date 08/11; Lot H109300, exp. date 08/11.