Z-1435-2011
IMPAX CV Results Manager/Results Manager Administration Tool The IMPAX Cardiovascular suite is a...
AGFA Healthcare Corp. / initiated 2009-04-15 / Terminated
AGFA Corp. began a recall of IMPAX CV Results Manager/Results Manager Administration Tool The IMPAX Cardiovascular suite is a cardiovascular information system providing image archiving... on . The reason FDA records is "User could modify a measurement's units and that change would not be reflected in echocardiography formulas used within the Adult echocardiography RM". As of , the recall status on record is Terminated.
Recall record
- Recall number
- Z-1435-2011
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- AGFA Healthcare Corp.
- Product
- IMPAX CV Results Manager/Results Manager Administration Tool The IMPAX Cardiovascular suite is a cardiovascular information system providing image archiving and image display and modality study-specific structured reporting. The suite is comprised of modular software that runs on industry standard personal computers and servers, utilizing Windows 2000/2003/XP operating systems. Image data storage/display utilizes DICO< (Digital Imaging and Communications in Medicine) data primarily from independent medical devices.
- Product code
- LLZ System, Image Processing, Radiological
- Reason for recall
- User could modify a measurement's units and that change would not be reflected in echocardiography formulas used within the Adult echocardiography RM.
- FDA root cause
- Other
- Action
- The firm, Agfa Healthcare, sent individual letters dating from April 15, 2009 to August 26, 2009, to the customers. The letters described the product, problem and actions to be taken. Agfa provided the affected customer with a complete list of their impacted patients and the measurements. Agfa also scheduled unit corrections with their customers and received acknowledgement of the letters at the time of scheduling the unit corrections. Service Bulletin DIS026.09E was issued January 2009 to inform users that Agfa will no longer allow customers to request unit changes for measurements that have formulas. Note: Technical Support ran diagnostic scripts for each customer and documented in GSC cases for each consignee/customer. If you have any questions, contact Agfa Healthcare at (949) 830-4959.
- Quantity in commerce
- 6 devices
- Distribution
- Nationwide distribution: USA including states of: IL, MT, NY, OR and SC.
- Product codes and lots
- Software Versions: RM 2.03, 2.04 & 2.06