Terumo Custom Integrated Cardioplegia Delivery Set-LINE FOR 15501/16015/5852 Item Number: 16110
Terumo Cardiovascular Systems Corp began a recall of Terumo Custom Integrated Cardioplegia Delivery Set-LINE FOR 15501/16015/5852 Item Number: 16110 Product Usage: This is a replacement line to multiple... on . FDA classified it as Class II and gives the reason as "Defect in the luer connector can compromise the seal on the female side of the connector. and the compromised seal can introduce air in the table line". As of , the recall status on record is Terminated, and MDM tags the root cause as design.
Recall record
- Recall number
- Z-0157-2015
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Terumo Cardiovascular Systems Corporation
- Product
- Terumo Custom Integrated Cardioplegia Delivery Set-LINE FOR 15501/16015/5852 Item Number: 16110 Product Usage: This is a replacement line to multiple Cardioplegia Delivery Sets - and includes the female luer connector that is the subject of this correction/removal activity
- Product code
- KRI Accessory Equipment, Cardiopulmonary Bypass
- Reason for recall
- Defect in the luer connector can compromise the seal on the female side of the connector. and the compromised seal can introduce air in the table line
- Root cause tag
- design
- FDA root cause
- Device Design
- Action
- Terumo Cardiovascualr notified accounts by letter dated 3/1/2011 advising users users that the luer connector to the table line in certain lots of myocardial protection sets may leak. Users should not continue to use affected myocardial protection sets in a manner that exposes the connector to negative pressure without taking correction or replacement activities as described. Firm provided mitigating instructions: Clamp the table line distal to the luer connector when ending an infusion of cardioplegia thus isolating the leak from negative pressure. Contact Terumo CVS Customer Service to report the defect and arrange return of the unit: 800-521-2818.
- Quantity in commerce
- 165 units
- Distribution
- Worldwide Distribution: US (nationwide) and the countries of Canada, Brazil, Hong Kong, Korea, and Thailand.
- Product codes and lots
- Lot Numbers: ML13, MM04. Manufacturing datese September 13, 2010 through October 4, 20 I 0.
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-0156-2015 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0157-2015 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0158-2015 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0159-2015 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0160-2015 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0161-2015 | Class II | Terminated | Voluntary: Firm initiated |