Terumo Custom Cardiovascular and Perfusion Procedure Kits Catalog Codes: Kits with a 5-digit code beginning...
Terumo Cardiovascular Systems Corp began a recall of Terumo Custom Cardiovascular and Perfusion Procedure Kits Catalog Codes: Kits with a 5-digit code beginning with the digit 6: Catalog Number: 6XXXX ; Catalog... on . FDA classified it as Class II and gives the reason as "Defect in the luer connector can compromise the seal on the female side of the connector and the compromised seal can introduce air in the table line". As of , the recall status on record is Terminated, and MDM tags the root cause as design.
Recall record
- Recall number
- Z-0159-2015
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Terumo Cardiovascular Systems Corporation
- Product
- Terumo Custom Cardiovascular and Perfusion Procedure Kits Catalog Codes: Kits with a 5-digit code beginning with the digit 6: Catalog Number: 6XXXX ; Catalog Codes: Kits with a 5-digit code beginning with the digit 7: Catalog Number: 7XXXX Product usage: The Cardioplegia Delivery Sets are indicated for delivery of cardioplegic solutions to the heart during cardiopulmonary bypass surgery. The Cardiovascular Procedure Kits are indicated for use only in the extracorporeal circuit for the cardiopulmonary bypass procedure(s) for which the user designed it.
- Product code
- OEZ Cardiovascular Procedure Kit
- Reason for recall
- Defect in the luer connector can compromise the seal on the female side of the connector and the compromised seal can introduce air in the table line.
- Root cause tag
- design
- FDA root cause
- Device Design
- Action
- Terumo Cardiovascualr notified accounts by letter dated 3/1/2011 advising users users that the luer connector to the table line in certain lots of myocardial protection sets may leak. Users should not continue to use affected myocardial protection sets in a manner that exposes the connector to negative pressure without taking correction or replacement activities as described. Firm provided mitigating instructions: Clamp the table line distal to the luer connector when ending an infusion of cardioplegia thus isolating the leak from negative pressure. Contact Terumo CVS Customer Service to report the defect and arrange return of the unit: 800-521-2818.
- Quantity in commerce
- Catalog Number: 6XXXX: 4561 units; Catalog Number: 7xxxx : 19356 units
- Distribution
- Worldwide Distribution: US (nationwide) and the countries of Canada, Brazil, Hong Kong, Korea, and Thailand.
- Product codes and lots
- Catalog Number: 6XXXX Lot Numbers: ML07, MM18, MM25, MN08, MN IS, MN22. Manufacturing dates September 7, 20 I 0 through November 22, 20 I 0. Catalog Number: 7XXXX Lot Numbers: ML07,ML20, MM18, MM25, MNO1, MN08, MN15, MN29,MP06, MP13. Manufacturing dates September 7, 2010 through December 13,2010.
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-0156-2015 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0157-2015 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0158-2015 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0159-2015 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0160-2015 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0161-2015 | Class II | Terminated | Voluntary: Firm initiated |