Getinge US Sales LLC
Wayne, NJ, US
GETINGE US SALES LLC appears in FDA device records in Wayne, NJ. FDA records list no 510(k) clearances, no PMA records and no registered establishments. As of , FDA records show 12 recalls for this company.
FDA records held for this company
- 510(k) clearances
- 0
- PMA records
- 0
- Recall records
- 12
- Registered establishments
- 0
510(k) clearance history
No 510(k) clearance records for this company in the ingested FDA data.
No 510(k) clearance records in the ingested FDA data.
Registered establishments
No FDA establishment registrations recorded against this company.
FDA product codes
No FDA product codes recorded against this company.
Recall records
| Recall | Product | Reason | Classification | Initiated | Status |
|---|---|---|---|---|---|
| Z-0677-2020 | Maquet Cardiopulmonary GmbH / Getinge Quadrox-iD Pediatric Diffusion Membrane Oxygenator with Bioline Coating, Sterile REF: BEQ-HMOD 30000 | Sterile barrier system may be compromised | Class II | Open, Classified | |
| Z-2559-2019 | The HEMASHIELD PLATINUM Woven Double Velour Vascular Graft is a woven double velour polyester graft impregnated with highly purified bovine collagen. The HEMASHIELD PLATINUM Woven Double Velour Vascular Graft is designed to reduce bleeding at implant and thereby eliminates the operative preclotting step, including cumbersome autoclave techniques. The collagen is designed to be gradually resorbed by the patient. The CONCENTRICRIMP pleat and GUIDELINE stripe are also featured. In addition to collagen, the graft also contains glycerol as a softening agent. | Based on an internal incident report, Getinge/Intervascular SAS has identified that the one (1) HEMASHIELD GOLD Knitted Microvel Double Velour Vascular Bifurcated Graft product with the diameter size of 16 x 9 mm is likely incorrectly packed inside of the carton which was labeled to contain a HEMASHIELD PLATINUM Woven Double Velour Vascular Graft product with the diameter size of 16 x 8 mm ((REF: M00202166168P0, Lot: 18K31, SN: 1190443415, size 16 x 8 mm). | Class II | Terminated | |
| Z-2433-2019 | Getinge MCC Flow i Disposable CO2 absorber, used in anesthesia systems. | Reversed expiration and manufacturing date on the label | Class II | Terminated | |
| Z-2077-2019 | PulsioFlex Monitoring System, Part Number: 6882747, Model Number: PC400 3 R0. Usage: The PulsioFlex Monitoring System is indicated in patients where cardiovascular and circulatory volume status monitoring is necessary. If a patient s biometric data are entered, the PulsioFlex Monitor presents the derived parameters indexed. -With the PiCCO Module cardiac output is determined both continuously through pulse contour analysis and intermittently through thermodilution technique. Both are used for the determination of other derived parameters. -With the CeVOX oximetry module connected to a compatible oximetry probe, the PulsioFlex Monitoring System measures continuous venous oxygen saturation to assess oxygen delivery and consumption. The use of the PulsioFlex Monitoring System is indicated in patients where cardiovascular and organ monitoring is useful. This includes patients in surgical, medical, and other hospital units | The monitor displays an error message . The error message states "internal error restart or service". | Class II | Terminated | |
| Z-1221-2019 | Maquet Servo-I Ventilator System -EDI CATHETER PHT Free 6Fr/49cm 5/pkg Product Code/REF Number: 6685775 Product Usage: The Edi Catheter is a single-use naso-gastric feeding tube with an electrode array of ten electrodes. The Edi Catheter is intended for: - Detecting diaphragmatic electrical activity, (Edi signals) by which the two ventilator modes NAVA and NIV NAVA can be controlled. - Detecting diaphragmatic electrical activity, (Edi signals) by which the respiratory drive from the brain can be monitored. - administrating nutrition, fluids and medications by the naso-gastricenteric route. | Edi Catheter labeled with wrong expiry date on single pack EDI catheter boxes | Class III | Terminated | |
| Z-0990-2019 | Maquet XS Flat Screen Monitor Holder, SAT XS32 12 SPE, Configuration Part Number ARD2SAT00130A Product Usage: This product is designed to support one or two medical grade flat screen(s) alone or in association with surgical lights. | The affected flat screen monitor holders might not be compliant with grounding requirements. As a consequence, there is a risk of mild to severe/fatal electric shock under certain conditions while using the flat screen monitor holder with voltage of 100-220V. | Class II | Terminated | |
| Z-0989-2019 | Maquet XS Flat Screen Monitor Holder, PWD70+DF HD R XS32 K3 SPE, Configuration Part Number ARD268400150A Product Usage: This product is designed to support one or two medical grade flat screen(s) alone or in association with surgical lights. | The affected flat screen monitor holders might not be compliant with grounding requirements. As a consequence, there is a risk of mild to severe/fatal electric shock under certain conditions while using the flat screen monitor holder with voltage of 100-220V. | Class II | Terminated | |
| Z-0988-2019 | Maquet XS Flat Screen Monitor Holder, PWD50+DF XS32 K3 SPE, Configuration Part Number ARD268400140A Product Usage: This product is designed to support one or two medical grade flat screen(s) alone or in association with surgical lights. | The affected flat screen monitor holders might not be compliant with grounding requirements. As a consequence, there is a risk of mild to severe/fatal electric shock under certain conditions while using the flat screen monitor holder with voltage of 100-220V. | Class II | Terminated | |
| Z-0987-2019 | Maquet XS Flat Screen Monitor Holder, XS32 SPE, Configuration Part Number ARD22201040A Product Usage: This product is designed to support one or two medical grade flat screen(s) alone or in association with surgical lights. | The affected flat screen monitor holders might not be compliant with grounding requirements. As a consequence, there is a risk of mild to severe/fatal electric shock under certain conditions while using the flat screen monitor holder with voltage of 100-220V. | Class II | Terminated | |
| Z-1349-2018 | VOLISTA StandOP Surgical Light; Model numbers VLT600 SF AIM STP, VLT600 DF AIM STP, Ref. codes ARD568811901, ARD568811911 ARD568811951, ARD568811961 The device is designed to illuminate the body of a patient during surgical operations, diagnostics and treatment. These surgical lights may be installed in surgical suites, examining rooms, doctors' surgeries and outpatient consultations. | The manufacturer received complaints indicating that the device's central handle holder detaches easily from the handle holder ring on the light head during clinical use. In the event of such detachment, particles from the handle holder ring could fall into the sterile field during a procedure. | Class II | Terminated | |
| Z-1172-2018 | HEMASHIELD Knitted Double Velour Cardiovascular Fabric | A probable mislabeling of the product: a different-sized product is referenced on the product packaging label (i.e. 2.5 cm (width) x 7.6 cm (length)) while the actual product inside the box is 2.5 cm (width) x 15 cm (length). | Class II | Terminated | |
| Z-1927-2018 | ALM XTEN Surgical Light intended to provide visible illumination for the surgical field or for the examination of the patient. Part Numbers: ARD567801093, ARD567801094 | Getinge has received complaints concerning the X TEN Surgical Lights whose spring arms have broken, causing light heads to separate from the assembly. The issue relates to cracking of the spring arms at the weld seams that has the potential to develop into breaks with heavy use and aging of the equipment. | Class II | Terminated |
Verification record
There is no verification record for this company. Most companies on this site have none: a record exists only where a company asked to be verified and MDM ran the checks, so the absence of one says nothing about the company.
Where there is a record, this is where it appears: what was checked, when it was checked, and the current status. An MDM Verified badge on another website links to a verify address on this domain that resolves to this section. A badge that does not resolve here is not ours.
MDM coverage
MDM coverage of this company lists here, newest first. Submit news.
Is this your company?
This page is built from public FDA records. Company pages are free and factual, and stay free whether or not anyone claims them. Membership never changes editorial coverage or vetting outcomes.
Claiming lets Getinge US Sales LLC edit what it says about itself and list the categories it works in. It grants no badge: claiming is not verification.
Data as of , FDA export datePage updated Source: openFDA, public domain