Medical Device
Manufacturing
THE TRADE PAPER OF THE FACTORY FLOOR

Gulf Fiberoptics, Inc.

Oldsmar, FL, US

GULF FIBEROPTICS, INC. appears in FDA device records in Oldsmar, FL. FDA records list 2 510(k) clearances between and , no PMA records and one registered establishment. As of , FDA records show 2 recalls for this company, and at least one establishment registration is current.

FDA records held for this company

510(k) clearances
2
PMA records
0
Recall records
2
Registered establishments
1

FDA records under these names

1 name

FDA records resolved to Gulf Fiberoptics, Inc. carry these names as well, as FDA wrote them. Each is the firm named on a registration, a 510(k), a PMA, a recall or an enforcement report that was joined to this company on a shared FDA identifier or on a matching name.

  • Gulf Medical Fiberoptics510(k), recall

510(k) clearance history

FDA records hold 2 510(k) clearances for Gulf Fiberoptics, Inc. between 2002 and 2006. The busiest year on record is 2002, with 1. The most recent is 2006, with 1.

Clearances by year, as a table
510(k) clearance decisions for Gulf Fiberoptics, Inc., by decision year
YearClearances
20021
20061
510(k) clearances on record, most recent first
K numberDeviceProduct codeDecisionDecision date
K061690SURGICAL HEADLIGHTFSTSubstantially Equivalent
K021931ENDOSCOPIC FIBEROPTIC CABLEHBISubstantially Equivalent

Registered establishments

FDA registered establishments for Gulf Fiberoptics, Inc., with the product codes listed at each
RegistrationFEIEstablishmentAddressRegistration expiresProduct codes listed
30037689213003768921GULF FIBEROPTICS, INC.448 Commerce Blvd, OLDSMAR, FL 34677 US2026

Registration numbers link to the FDA registration and listing record for that establishment.

FDA product codes

Recall records

Device recall records naming this company, most recent first
RecallProductReasonClassificationInitiatedStatus
Z-2029-2012GMF-RC65 Replacement Surgical Headlight Cable for Cogent Microlink. GMF-RC65 Replacement Surgical Headlight Cable for Cogent Microlink is used to transmit light.The GMF-RC65 Replacement Surgical Headlight Cable for Cogent Microlink falls outside of the firm's 510k due to light transmitting fiber material difference.Class IITerminated
Z-0831-2012Surgical Headlight labeled in part *Gulf Medical Fiberoptics*OLDSMAR, FLORIDA U.S.A.* Model Numbers: GMF-H001, GMF-H100, GMF-H101, GMF-H102, GMF-H103, GMF-H104, GMF-H105, and GMF-H106. The Surgical Headlight is a passive luminaire. It is illuminated by a source of light by way of the fiber optics and provides supplemental lighting for medical and surgical procedures.Gulf Medical Fiberoptics, Inc. recalled their Surgical Headlight because the cleaning instructions for the exterior surfaces of the headlight , headgear and fiber cable with 70% isopropyl alcohol had not been validated.Terminated

Verification record

There is no verification record for this company. Most companies on this site have none: a record exists only where a company asked to be verified and MDM ran the checks, so the absence of one says nothing about the company.

Where there is a record, this is where it appears: what was checked, when it was checked, and the current status. An MDM Verified badge on another website links to a verify address on this domain that resolves to this section. A badge that does not resolve here is not ours.

What MDM checks, and what it does not

MDM coverage

MDM coverage of this company lists here, newest first. Submit news.

Is this your company?

This page is built from public FDA records. Company pages are free and factual, and stay free whether or not anyone claims them. Membership never changes editorial coverage or vetting outcomes.

Claiming lets Gulf Fiberoptics, Inc. edit what it says about itself and list the categories it works in. It grants no badge: claiming is not verification.

Claim this page