Medtronic Neurosurgery appears in FDA device records in Fort Worth, TX. FDA records list 28 510(k) clearances between and , no PMA records and one registered establishment. As of , FDA records show 68 recalls for this company, and at least one establishment registration is current.
FDA records held for this company
510(k) clearance history
FDA records hold 28 510(k) clearances for Medtronic Neurosurgery between 2001 and 2025. The busiest year on record is 2004, with 5. The most recent is 2025, with 1.
Clearances by year, as a table
| Year | Clearances |
|---|---|
| 2001 | 1 |
| 2004 | 5 |
| 2005 | 4 |
| 2006 | 4 |
| 2007 | 1 |
| 2008 | 3 |
| 2009 | 1 |
| 2011 | 1 |
| 2013 | 1 |
| 2014 | 1 |
| 2016 | 2 |
| 2018 | 1 |
| 2021 | 1 |
| 2024 | 1 |
| 2025 | 1 |
| K number | Device | Product code | Decision | Decision date |
|---|---|---|---|---|
| K243676 | Duet External Drainage and Monitoring System (EDMS) | JXG | Substantially Equivalent | |
| K242034 | Duet External Drainage and Monitoring System (EDMS) | PCB | Substantially Equivalent | |
| K212641 | StrataMR II Valves and Shunts | JXG | Substantially Equivalent | |
| K181622 | StrataMR guider tool | JXG | Substantially Equivalent | |
| K161370 | Durepair Dura Regeneration Matrix | GXQ | Substantially Equivalent | |
| K152700 | StrataMR Valves and Shunts | JXG | Substantially Equivalent | |
| DEN120017 | Medtronic DUET External Drainage and Monitoring System | PCB | Unknown | |
| K123524 | MEDTRONIC STRATA NSC LUMBOPERITONEAL VALVE AND SHUNT SYSTEM | JXG | Substantially Equivalent | |
| K110560 | MEDTRONIC ARES ANTIBIOTIC-IMPREGNATED CATHETER | JXG | Substantially Equivalent | |
| K091312 | PS MEDICAL STRATA NSC LUMBOPERITONEAL VALVE AND SHUNT SYSTEM | JXG | Substantially Equivalent | |
| K083076 | STRATA BURR HOLE VALVE, MODEL 42836 AND STRATA BURR HOLE SHUNT ASSEMBLY, MODEL 46836 | JXG | Substantially Equivalent | |
| K082127 | STRATA NSC BURR HOLE VALVE, MODEL 42335; SHUNT ASSEMBLY, MODEL 46635 | JXG | Substantially Equivalent | |
| K073139 | SMALL LUMEN PERITONEAL CATHETER | JXG | Substantially Equivalent | |
| K063836 | RIVULET VENTRICULAR AND SNAP SHUNT AND CONVERTIBLE VENTRICULAR CATHETERS, MODELS 41701 AND 41704-41715 | JXG | Substantially Equivalent | |
| K062821 | U-CLIP DEVICE | FZP | Substantially Equivalent | |
| K063117 | MODIFICATION TO DUREPAIR DURA REGENERATION MATRIX | GXQ | Substantially Equivalent | |
| K060681 | MEDTRONIC PS MEDICAL STRATA TYPE VALUE | JXG | Substantially Equivalent | |
| K062348 | TIMESH SELF DRILLING SCREW | HWC | Substantially Equivalent | |
| K052386 | MEDTRONIC M2 MAGNET ADJUSTMENT TOOL | JXG | Substantially Equivalent | |
| K052211 | DUREPAIR DURA REGENERATION MATRIX | GXQ | Substantially Equivalent | |
| K050044 | MEDTRONIC CLIP GUN KIT | HBO | Substantially Equivalent | |
| K041992 | MEDTRONIC STRATAVARIUS | JXG | Substantially Equivalent | |
| K042465 | PS MEDICAL STRATA II VALVE | JXG | Substantially Equivalent | |
| K042198 | PS MEDICAL NEUROSURGICAL IMPLANTS | JXG | Substantially Equivalent | |
| K041000 | DUREPAIR DURA REGENERATION MATRIX | GXQ | Substantially Equivalent | |
| K040943 | MEDTRONIC PS MEDICAL STRATA VALVE | JXG | Substantially Equivalent | |
| K033850 | MEDTRONIC PS MEDICAL STRATA NSC VALVE AND SHUNT ASSEMBLIES WITH AND WITHOUT BIOGLIDE | JXG | Substantially Equivalent | |
| K013000 | MEDTRONIC INVISX BURR HOLE LOCK, MODEL 60520 | GXN | Substantially Equivalent |
Registered establishments
| Registration | FEI | Establishment | Address | Registration expires | Product codes listed |
|---|---|---|---|---|---|
| 3015531529 | 3015531529 | Medtronic Neurosurgery | 4620 North Beach Street, Fort Worth, TX 76137 US | 2026 | and 11 more, listed in full below |
Registration numbers link to the FDA registration and listing record for that establishment.
FDA product codes
- MAJCatheter, Percutaneous, Intraspinal, Short Term
- HCACatheter, Ventricular
- FZPClip, Implantable
- HBOClip, Scalp
- GXRCover, Burr Hole
- GWMDevice, Monitoring, Intracranial Pressure
- HBGDrills, Burrs, Trephines & Accessories (Manual)
- GXQDura Substitute
- GEIElectrosurgical, Cutting & Coagulation & Accessories
- GWGEndoscope, Neurological
- FETEndoscopic Video Imaging System/Component, Gastroenterology-Urology
- PCBExternal Cerebrospinal Fluid (Csf) Diversion
- GYKInstrument, Shunt System Implantation
- GCTLight Source, Endoscope, Xenon Arc
- FTMMesh, Surgical
- EZXMesh, Surgical, Metal
- JEYPlate, Bone
- GXNPlate, Cranioplasty, Preformed, Non-Alterable
- HRSPlate, Fixation, Bone
- LJTPort & Catheter, Implanted, Subcutaneous, Intravascular
- LKGPort & Catheter, Implanted, Subcutaneous, Intraventricular
- HWCScrew, Fixation, Bone
- JXGShunt, Central Nervous System And Components
Recall records
Showing 25 of 68| Recall | Product | Reason | Classification | Initiated | Status |
|---|---|---|---|---|---|
| Z-2768-2026 | Ventriculostomy Kit, REF: 46154 | Ventriculostomy devices, used during ventriculostomy procedures to gain access to the ventricular system, may exhibit endotoxin levels that exceed the acceptable limit for devices that come into contact with cerebrospinal fluid; endotoxin exposure can cause an acute inflammatory process. | Class II | Open, Classified | |
| Z-0662-2025 | Exacta External Drainage and Monitoring System: 27581 KIT 27581 EXACTA W/EDM VCATH 35CM 27636 EDM 27636 EXACTA W/BRAIDED CORD LOCK 27666 EDM 27666 EXCTA W GLUE STPCK GR PT LN 27732 EDM 27732 EXACTA W/NDL-LS INJ. ST W/CAP 27785 EDMS 27785 EXACTA 50ML BC NDLESS INJ 27795 EDMS 27795 EXACTA 100ML CATH 27861 EDMS 27861 EXACTA 50ML ANTIRFLUX GRNPL 46700 SYSTEM 46700 EXACTA DISP. DRAINAGE 46705 SYSTEM 46705 EXACTA DRAINAGE 100ML The Exacta external drainage and monitoring system (EDMS) is a system for externally draining and monitoring cerebrospinal fluid (CSF) and monitoring intracranial pressure (ICP). | Due to complaints received reporting cracks and/or leaks of the stopcocks associated with the external drainage and monitoring system (EDMS). | Class I | Open, Classified | |
| Z-0661-2025 | Becker External Drainage and Monitoring System: 24146 EDMS 24146 BECKER NO Y-SITE 25120 EDMS II 25120 BECKER W/1-WAY VALVE 26040 KIT 26040 BECKER EDMS II 27609 BECKER 27609 W/NEEDLESLESS INJ. SITE 27670 BECKER 27670 STOP BELOW DC NDL-LS IN 27672 BECKER 27672 ONEWAY VLV Y-SITE PT LN 27702 EDMS 27702 EURO BECKER II GR PT LN 27761 BECKER 27761 STOP BCNDLESS PATLN 24 27767 BECKER 27767 NO STPCOCK ON PTLN 63 27779 EDMS 27779 BECKER BC NDLESS BOND CONN 27811 EDMS 27811 BECKER GRN PL VCATH 27931 EDMS 27931 BECKER GS TUBING SMARTSITES 46128 EDMS 46128 BECKER II BLUE PT LN 46129 EDMS 46129 EURO BECKER II BLUE PT LN The Becker External Drainage and Monitoring System (Becker EDMS) is a closed system for: 1. Draining cerebrospinal fluid (CSF) from the lateral ventricles of the brain or the lumbar subarachnoid space. 2. Monitoring CSF pressure and flow rate from the lateral ventricles of the brain and the lumbar subarachnoid space. | Due to complaints received reporting cracks and/or leaks of the stopcocks associated with the external drainage and monitoring system (EDMS). | Class I | Open, Classified | |
| Z-1166-2024 | Medtronic Duet External Drainage and Monitoring System, Interlink Injection Sites, Lumbar Catheter, REF 46917, Sterile EO, Rx Only. Used to drain cerebrospinal fluid (CSF) as a means to reduce intracranial pressure and CSF volume. | Potential for catheter disconnection from the patient line stopcock connectors. | Class I | Open, Classified | |
| Z-1165-2024 | Medtronic Duet External Drainage and Monitoring System, SmartSite Injection Sites, Ventricular Catheter, REF 46916, Sterile EO, Rx Only. Used to drain cerebrospinal fluid (CSF) as a means to reduce intracranial pressure and CSF volume. | Potential for catheter disconnection from the patient line stopcock connectors. | Class I | Open, Classified | |
| Z-1164-2024 | Medtronic Duet External Drainage and Monitoring System, Interlink Injection Sites, Ventricular Catheter, REF 46915, Sterile EO, Rx Only. Used to drain cerebrospinal fluid (CSF) as a means to reduce intracranial pressure and CSF volume. | Potential for catheter disconnection from the patient line stopcock connectors. | Class I | Open, Classified | |
| Z-1163-2024 | Medtronic Duet External Drainage and Monitoring System, SmartSite, Injection Sites, REF 46914, Sterile EO, Rx Only. Used to drain cerebrospinal fluid (CSF) as a means to reduce intracranial pressure and CSF volume. | Potential for catheter disconnection from the patient line stopcock connectors. | Class I | Open, Classified | |
| Z-1162-2024 | Medtronic Duet External Drainage and Monitoring System, Interlink Injection Sites, REF 46913, Sterile EO, Rx Only. Used to drain cerebrospinal fluid (CSF) as a means to reduce intracranial pressure and CSF volume. | Potential for catheter disconnection from the patient line stopcock connectors. | Class I | Open, Classified | |
| Z-2412-2023 | Medtronic REF 46915 Duet External Drainage and Monitoring system, Interlink Injection sites, Ventricular Catheter, STERILE EO, Rx Only | Product labeling contains incorrect expiration date | Class II | Open, Classified | |
| Z-2207-2023 | Durepair Dura Regeneration Matrix: DUREPAIR DURA SUBSTITUTE 2 X 2, 61100; DUREPAIR DURA SUBSTITUTE 3 X 3, 61105; DUREPAIR DURA SUBSTITUTE 1 X 3, 61106; DUREPAIR DURA SUBSTITUTE 4 X 5, 61110; DUREPAIR DURA SUBSTITUTE 1 X 1, 61111; DURA 62100 SUBSTITUTE DUREPAIR 2X2IN NCE, 62100; DURA 62105 SUBSTITUTE DUREPAIR 3X3IN NCE, 62105; DURA 62106 SUBSTITUTE DUREPAIR 1X3IN NCE, 62106; DURA 62110 SUBSTITUTE DUREPAIR 4X5IN NCE, 62110; DURA 62111 SUBSTITUTE DUREPAIR 1X1IN NCE, 62111; DURA 62158 SUBSTITUTE DUREPAIR 5X8IN NCE, 62158. | Dura regeneration matrix may have out-of-specification endotoxin levels due to issues with in-process and finished goods endotoxin testing, which may present clinically with signs and symptoms of an acute inflammatory process, comparable to infection. | Class II | Open, Classified | |
| Z-1117-2021 | Medtronic PS Medical Cerebro Spinal Fluid (CSF)-Flow Control Valves for the following CFNs: 22011 L- SHUNT 22011 L INTL ONLY ULTRA SM LOW 22011 LL - SHUNT 22011 LL INTL ONLY ULTRA SM L-L 22011 M - SHUNT 22011 M INTL ONLY ULTRA SM MED 22017 B-L - SHUNT 22017 B-L ASSY US PER 90CM SM LOW 22017 B-M - SHUNT 22017 B-M ASSY US PER 90CM SM MED 22017B-LL - SHUNT 22017B-LL ASSY US PER 90CM SM LL 23093 - VALVE 23093 CONT. REG. LOW-LOW 27102 - VALVE 27102 CONTOURED SML LOW LOW 27553 M - VALVE 27553 M CSF-FLOW CNTRL SM EXTR MP 27643M - SHUNT 27643M ASSY SM PCATH130CM MED 27683M - SHUNT 27683M RG SNP PCATH90 PLI STD OE 42312 - VALVE 42312 SM CONTOURED LOW PRES IMP 42314- VALVE 42314 SM CONTOURED MED PRESS IMP 42316 - VALVE 42316 SM CONTOURED HIGH PRESS 42322 - VALVE 42322 CONTOURED REG LOW PRESS IMP 42324 - VALVE 42324 CONTOURED REG MED PRESS IMP 42326 - VALVE 42326 CONT HIGH PRESS IMP 42410 - VALVE 42410 ULTRA SMALL LOW-LOW 42414 - VALVE 42414 ULTRA SMALL MEDIUM PRESS IMP 42532 - VALVE 42532 BURR HOLE 12MM LOW PRESS IMP 42534 - VALVE 42534 BURR HOLE 12MM MED PRESS IMP 42536 - VALVE 42536 BURR HOLE 12MM HI PRESS IMP 42542 - VALVE 42542 BURR HOLE 16 MM LOW IMP 42544 - VALVE 42544 BURR HOLE 16MM MED PRESS IMP 42546 - VALVE 42546 BURR HOLE 16MM HI PRESS IMP 46564 - SHUNT 46564 CSF SNAP ASSY US MEDIUM 46622 - SHUNT 46622 CSF ASSY SMALL LOW CONT C/P 46624 - SHUNT 46624 CSF ASSY SMALL MED CONT C/P 46626 - SHUNT 46626 CSF ASSY SMALL HIGH CONT C/P 46642 - SHUNT 46642 ASSY REG LOW C/P-90CM 46644 - SHUNT 46644 ASSY REG MED C/P-90CM 46646 - SHUNT 46646 ASSY REG HIGH C/P-90CM 9003 A - KIT 9003 A INTL ONLY SHUNT CONT SM LO 9003 B - KIT 9003 B INTL ONLY SHUNT CONT SM ME 9003 C - KIT 9003 C INTL ONLY SHUNT CONT SM HI 9003 D - KIT 9003 D SHUNT INTL ONLY CONT REG L 9003 E - KIT 9003 E SHUNT INTL ONLY CONT REG M 9003 F - KIT 9003 F SHUNT INTL ONLY CONT REG H 9040 A - KIT 9040 A SHUNT INTL ONLY BH 12MM LOW 9040 B - KIT 9040 B SHUNT INTL ONLY BH 12MM MED 9040 C - KIT 9040 C SHUNT INTL ONLY BH 12MM HIGH 9040 D - KIT 9040 DSHUNT INTL ONLY BH 16MM LOW 9040 E - KIT 9040 E SHUNT INTL ONLY BH 16MM MED 9040 F - KIT 9040 A SHUNT INTL ONLY BH 12MM LOW 92322 - VALVE 92322 CSF CONT REG LOW BIO 92324 - VALVE 92324 CSF CONT REG MED BIO | Potential for variation in radiopaque marking visibility under radiographic imaging for adjustable and fixed-pressure valves that are used in the management of hydrocephalus | Class II | Open, Classified | |
| Z-1116-2021 | Medtronic Cerebro Spinal Fluid Flow Control Valves and Shunts. STRATA II Valves and Shunts for the following CFNs: 27739 - SHUNT 27739 STRATA NSC SNAP SML 120CM, 27740 - SHUNT 27740 STRATA NSC SNAP REG 120CM, 27812 - VALVE 27812 STRATA II SM EXTRACTED, 27814 - SHUNT 27814 STRATA II ASSY SML, 27815 - SHUNT 27815 STRATA II ASSY REG, 27816 - SHUNT 27816 SNAP STRATA II SMALL, 27817 - SHUNT 27817 SNAP STRATA II REG, 27818 - SHUNT 27818 STRATA II SML BIO, 27819 - SHUNT 27819 STRATA II REG BIO, 27823 - SHUNT 27823 STRATA II ASSY SNP REG BIO, 27827 - VALVE 27827 STRATA II REG EXTRACTED, 27888 - SHNT 27888 STRATA II SNAP ASSY REG PCATH, 42335 - VALVE 42335 STRATA NSC BURR HOLE, 42355 - VALVE 42355 FP STRATA NSC SMALL, 42365 - VALVE 42365 FP STRATA NSC REGULAR, 42836 - VALVE 42836 STRATA II BURR HOLE, 42856 - VALVE 42856 FP-STRATA 2 SMALL, 42866 - ASSY 46866 FP-STRATA 2 SHUNT REG, 44420 - SHUNT 44420 STRATA KIT NSC LP, 44421 - KIT 44421 STRATA NSC LP OPEN LUMBAR, 44430 - SHUNT 44430 STRATA KIT NSC LP ASSY, 44465 - VALVE 44465 STRATA NSC LP, 46636 - SHUNT 46636 STRATA NSC BURR, 46655 - ASSY 46655 FP SHUNT STRATA NSC SMALL, 46665 - ASSY 46665 FP SHUNT STRATA NSC REG, 46837 - SHUNT 46837 STRATA II BURR HOLE, 46856 - ASSY 46856 FP-STRATA 2 SHUNT SML, 46866 - ASSY 46866 FP-STRATA 2 SHUNT REG, 92355 - VALVE 92355 STRATA NSC SML BIOGLIDE, 92856 - VALVE 92856 FP STRATA 2 SML BG, 92866 - VALVE 92866 FP STRATA 2 REG BG, | Potential for variation in radiopaque marking visibility under radiographic imaging for adjustable and fixed-pressure valves that are used in the management of hydrocephalus | Class II | Open, Classified | |
| Z-1115-2021 | Medtronic Delta CSF (Cerebro Spinal Fluid) -Flow Control Valves for the following CFNs/REF numbers: 24048 - VALVE 24048 DELTA RGL PL 0.5, 24053 - CHAMBER 24053 DELTA, 24147 - VALVE 24147 DELTA SML PL0.5, 25121-1 - ASSY 25121-1 DELTA SML SNAP PERIT 120, 25121-5 - ASSY 25121-5 DELTA SML SNAP P-CATH 120, 25131-1 - DELTA 25131-1 INTL ONLY SHUNT SM 1.0, 25131-2 - SHUNT 25131-2 INTL ONLY DELTA SM 2.0, 25131-5 - SHUNT 25131-5 INTL ONLY DELTA SM 1.5, 25132-2 - SHUNT 25132-2 INTL ONLY DELTA REG.2.0, 25132-5 - SHUNT 25132-5 INTL ONLY DELTA REG 1.5, 27219-1 - VALVE 27219-1 NEONATE DELTA, 27219-2 - VALVE 27219-2 NEONATE DELTA, 27219-5 - VALVE 27219-5 DELTA NEONATE 1.5 IMP, 27554-1 - VALVE 27554-1 DELTA SM EXTRACTED PL 1.0, 27554-2 - VALVE 27554-2 DELTA SM EXTRACTED PL 2.0, 27554-5 - VALVE 27554-5 DELTA SM EXTRACTED PL 1.5, 42812 - VALVE 42812 DELTA SMALL LEVEL I, 42813 - VALVE 42813 DELTA SMALL LEVEL 1.5, 42814 - VALVE 42814 DELTA SMALL LEVEL II, 42822 - VALVE 42822 DELTA REG PRESS LEVEL I IMP, 42823 - VALVE 92823 BIOGLIDE DELTA REG. 1.5, 42824 - VALVE 42824 DELTA REG PRESS LEVEL II IMP, 46812 - ASSY 46812 DELTA SHUNT SMALL PL 1, 46813 - ASSY 46813 DELTA SHUNT SM LEV 1.5, 46822 - ASSY 46822 DELTA SHUNT REG P/L 1, 46823 - ASSY 46823 DELTA SHUNT REG LEV 1.5, 46824 - ASSY 46824 DELTA SHUNT REG P/L 2, 46832 - SHUNT 46832 NEONATAL DELTA SNAP L 1, 46833 - SHUNT 46833 NEONATAL DELTA SNAP 1.5, 46834 - SHUNT 46834 NEONATAL DELTA SNAP L 2, 92822 - VALVE 92822 BIOGLIDE DELTA REG. 1.0, 92823 - VALVE 92823 BIOGLIDE DELTA REG. 1.5, | Potential for variation in radiopaque marking visibility under radiographic imaging for adjustable and fixed-pressure valves that are used in the management of hydrocephalus | Class II | Open, Classified | |
| Z-0873-2021 | REF 27219-5 X1, Medtronic, Delta Valve, Neonatal, Performance Level 1.5, CE 0344, Sterile EO - Product Usage: Neonatal Delta Snap Shunt Assemblies are components of CSF-Flow Control Shunt Systems designed to provide controlled CSF flow from the ventricles of the brain into the peritoneal cavity. | Neonatal Valves were manufactured with a ventricular catheter connection site shorter than the design specification. The defect can lead to difficulty in securing the valve to the proximal catheter which could result in disconnection of the ventricular catheter from the valve and shunt malfunction | Class II | Open, Classified | |
| Z-0872-2021 | REF 27219-2 X1, Medtronic, Delta Valve, Neonatal, Performance Level 2.0, CE 0344, Sterile EO - Product Usage: Neonatal Delta Snap Shunt Assemblies are components of CSF-Flow Control Shunt Systems designed to provide controlled CSF flow from the ventricles of the brain into the peritoneal cavity. | Neonatal Valves were manufactured with a ventricular catheter connection site shorter than the design specification. The defect can lead to difficulty in securing the valve to the proximal catheter which could result in disconnection of the ventricular catheter from the valve and shunt malfunction | Class II | Open, Classified | |
| Z-0871-2021 | REF 27219-1 X1, Medtronic, Delta Valve, Neonatal, Performance Level 1.0, CE 0344, Sterile EO - Product Usage: Neonatal Delta Snap Shunt Assemblies are components of CSF-Flow Control Shunt Systems designed to provide controlled CSF flow from the ventricles of the brain into the peritoneal cavity. | Neonatal Valves were manufactured with a ventricular catheter connection site shorter than the design specification. The defect can lead to difficulty in securing the valve to the proximal catheter which could result in disconnection of the ventricular catheter from the valve and shunt malfunction | Class II | Open, Classified | |
| Z-0740-2021 | Medtronic Ares Antibiotic-Impregnated Catheter, REF: 95001, Sterile, Rx Only. Used in the treatment of hydrocephalus as a component of a shunt system when draining or shunting of cerebrospinal fluid (CSF) is indicated. | There is a potential for a defect on the seal of the outer pouch of catheters. The defect may compromise the sterility of the pouch contents, which may increase the risk of post-operative infection, requiring further medical intervention. | Class II | Open, Classified | |
| Z-0739-2021 | Medtronic Ares Antibiotic-Impregnated Catheter, REF: 93092, Sterile, Rx Only. Used in the treatment of hydrocephalus as a component of a shunt system when draining or shunting of cerebrospinal fluid (CSF) is indicated. | There is a potential for a defect on the seal of the outer pouch of catheters. The defect may compromise the sterility of the pouch contents, which may increase the risk of post-operative infection, requiring further medical intervention. | Class II | Open, Classified | |
| Z-0738-2021 | Medtronic Ares Antibiotic-Impregnated Catheter, REF: 91101, Sterile, Rx Only. Used in the treatment of hydrocephalus as a component of a shunt system when draining or shunting of cerebrospinal fluid (CSF) is indicated. | There is a potential for a defect on the seal of the outer pouch of catheters. The defect may compromise the sterility of the pouch contents, which may increase the risk of post-operative infection, requiring further medical intervention. | Class II | Open, Classified | |
| Z-3212-2018 | Medtronic Clip Gun Magazines are packaged in individually sealed pouches and distributed in boxes containing 5 individually pouched Clip Gun Magazine. REF CM8902, Medtronic Clip Gun Magazine, Rx only, CE 0344, STERILE EO, Rx only, Single Use | The packaging sterile barrier does not comply with the applicable packaging standard for terminally sterilized medical devices. While the Instructions for Use (IFU) state Do not use if package has been previously opened or damaged , it is possible that the seal breach may go undetected by the user's naked eye. | Class II | Terminated | |
| Z-0622-2018 | Model #: CG8900, Medtronic Clip Gun Scalp Clip Kit (Qty 1); Model #: CG8901, Medtronic Clip Gun Scalp Clip Kit (Qty 10); Model #: CG8901A, Medtronic Clip Gun Applicator (Qty 10) | Medtronic is initiating a voluntary recall because the products identified above did not adequately demonstrate acceptable packaging performance to current standards. | Class II | Terminated | |
| Z-1702-2017 | The Medtronic StrataMR adjustable valves and shunts are designed to provide continuous cerebrospinal fluid (CSF) flow from the ventricles of the brain into the right atrium of the heart or the peritoneal cavity. The design enables the physician to non-invasive adjust valve pressure/performance level pre- and post-implantation by using magnetic adjustment tools without the need for radiographic confirmation. After surgical implantation, the Medtronic Neurosurgery StrataMR valves provide a non-invasive method to address changing patient needs in the management of hydrocephalus. The valve design enables the physician to adjust the valve pressure/performance level using the Medtronic StrataMR Adjustment Tools. The StrataMR valves are intended to maintain performance level setting under magnetic resonance imaging (MRI) exposure when scanned in accordance with the MRI conditions in the labeling. The StrataMR valves, small and regular, provide the full range of performance levels: 0.5, 1.0, 1.5, 2.0, and 2.5. The currently set performance level is discernible through use of the Indicator Tool or by x-ray (for corresponding settings, refer to figure 6). The dome is designed to allow needle puncture via a 25-gauge or smaller noncoring needle. The StrataMR valve can be flushed in either the distal or proximal direction by percutaneous finger pressure. Occluders are located proximally and distally to the central reservoir on the StrataMR valve regular and only distally on the small model to facilitate selective flushing. | Incorrect valve rotor orientation due to misalignment and/or off-center positioning of the StrataMR Locator Tool: When the StrataMR valve is set in the incorrect orientation, higher valve opening pressures result leading to a corresponding underdrainage in CSF fluid performance. This condition may result in the following adverse health consequences: ventriculomegaly, headaches, nausea, vomiting and lethargy. If left untreated, underdrainage has the potential to lead to coma and death. | Class I | Terminated | |
| Z-1121-2017 | Medtronic Strata II / Strata NSC Valves (includes Burr Hole and Lumbar Peritoneal. All Catalog Numbers. Strata-type valves are used in the management of hydrocephalus. The Strata II/Strata NSC valve is a shunt component designed to allow for continuous flow of cerebrospinal fluid (CSF) from the ventricles of the brain to the peritoneal cavity or right atrium of the heart. mechanism. Strata Valve Magnet Reverse Polarity (Excludes StrataMR). Catalog No. 27739 27740 27786 27787 27788 27789 27794 27812 27814 27815 27816 27817 27818 27820 27821 27822 27823 27824 27825 27827 27828 27830 27831 27832 27848 27864 27867 27868 27888 27903 27922 27823 27924 23042 27925 27926 27927 27932 27933 42335 42355 42365 42836 42856 42866 44420 44421 44430 44465 46070 46075 46080 46085 46635 46655 46665 46836 46856 46866 46871 46876 46881 46886 92355 92365 92856 92866 96655 96665 | Medtronic Neurosurgery initiated a recall after receiving five (5) Product Experiences between February 15, 2015 and August 23, 2016 reporting of discrepancies between the pressure/performance level (PL) at which the valve was set and the readings determined via an x-ray image. | Class II | Terminated | |
| Z-1924-2014 | Medtronic Duet External Drainage and Monitoring System, Interlink Injection Sites, Lumbar Catheter, Catalog No. 46917. Intended to allow drainage and measurement of cerebrospinal fluid (CSF) and other fluids of similar physical character from the ventricles or the lumbar subarachnoid (intrathecal) region. | Medtronic Neurosurgery is recalling the Medtronic Duet External Drainage and Monitoring Systems because the patient line tubing in the Duet External Drainage and Monitoring Systems may become disconnected from the patient line stopcock. | Class I | Terminated | |
| Z-1923-2014 | Medtronic Duet External Drainage and Monitoring System, SmartSite Injection Sites, Ventricular Catheter, Catalog No. 46916. Intended to allow drainage and measurement of cerebrospinal fluid (CSF) and other fluids of similar physical character from the ventricles or the lumbar subarachnoid (intrathecal) region. | Medtronic Neurosurgery is recalling the Medtronic Duet External Drainage and Monitoring Systems because the patient line tubing in the Duet External Drainage and Monitoring Systems may become disconnected from the patient line stopcock. | Class I | Terminated |
Verification record
There is no verification record for this company. Most companies on this site have none: a record exists only where a company asked to be verified and MDM ran the checks, so the absence of one says nothing about the company.
Where there is a record, this is where it appears: what was checked, when it was checked, and the current status. An MDM Verified badge on another website links to a verify address on this domain that resolves to this section. A badge that does not resolve here is not ours.
MDM coverage
MDM coverage of this company lists here, newest first. Submit news.
Is this your company?
This page is built from public FDA records. Company pages are free and factual, and stay free whether or not anyone claims them. Membership never changes editorial coverage or vetting outcomes.
Claiming lets Medtronic Neurosurgery edit what it says about itself and list the categories it works in. It grants no badge: claiming is not verification.
Data as of , FDA export datePage updated Source: openFDA, public domain