Medical Device
Manufacturing
THE TRADE PAPER OF THE FACTORY FLOOR

Penlon, Ltd.

ABINGDON Oxfordshire, GB

PENLON LTD. appears in FDA device records in ABINGDON Oxfordshire, GB. FDA records list 22 510(k) clearances between and , no PMA records and one registered establishment. As of , FDA records show 4 recalls for this company, and at least one establishment registration is current.

FDA records held for this company

510(k) clearances
22
PMA records
0
Recall records
4
Registered establishments
1

FDA records under these names

1 name

FDA records resolved to Penlon, Ltd. carry these names as well, as FDA wrote them. Each is the firm named on a registration, a 510(k), a PMA, a recall or an enforcement report that was joined to this company on a shared FDA identifier or on a matching name.

  • Penlon, Ltd. (Fmly East Healthcare)recall

510(k) clearance history

FDA records hold 22 510(k) clearances for Penlon, Ltd. between 1980 and 2006. The busiest year on record is 2001, with 3. The most recent is 2006, with 3.

Clearances by year, as a table
510(k) clearance decisions for Penlon, Ltd., by decision year
YearClearances
19802
19812
19831
19852
19891
19901
19941
19952
19962
20013
20041
20051
20063
510(k) clearances on record, most recent first
K numberDeviceProduct codeDecisionDecision date
K061102PRIMA ANAESTHESIA MACHINEBSZSubstantially Equivalent
K060331SIGMA ALPHA VAPORIZERCADSubstantially Equivalent
K053564KEYED FILLER BOTTLE ADAPTOR, MODELS 53450, 53452, 53453, 53454CADSubstantially Equivalent
K051222AV-S ANAESTHESIA VENTILATORCBKSubstantially Equivalent
K041076DELTA TCADSubstantially Equivalent
K010318PRIMA OXYGEN MONITORCCLSubstantially Equivalent
K010317AV 800 VENTILATORCBKSubstantially Equivalent
K002343SIGMA DELTACADSubstantially Equivalent
K961468QUIK-FIL VAPORIZER KEYED FILLERCADSubstantially Equivalent
K960944PPV VAPORIZER (MODIFICATION)CADSubstantially Equivalent
K953179CLM LARYNGOSCOPECCWSubstantially Equivalent
K942545SIGMA ELITECADSubstantially Equivalent
K936046SIGMA ELITECADSubstantially Equivalent
K902381PENLON BREATHING SYSTEM PRESSURE MONITORCAPSubstantially Equivalent
K894689PENLON IDP PRESSURE FAILURE ALARMCAPSubstantially Equivalent
K844008PENLON AM1000 ANAESTHESIA MACHINEBSZSubstantially Equivalent
K844007PENLON PPV VAPORIZERCADSubstantially Equivalent
K823555MAGTARAK RESPIRATORY MONITOR & FLOW SENSBZKSubstantially Equivalent
K803052NUFFIELD ANESTHESIA VENTILATOR SER. 400BSZSubstantially Equivalent
K801253CREST ELECTRONIC WARMING BLANKETDWJSubstantially Equivalent
K801254PENLON I.D.P. PRESSSURE FAILURE ALARMCAPSubstantially Equivalent
K801255PENLON JUMBO CARBON DIOXIDE ABSORBERBSFSubstantially Equivalent

Registered establishments

FDA registered establishments for Penlon, Ltd., with the product codes listed at each
RegistrationFEIEstablishmentAddressRegistration expiresProduct codes listed
96105313002807907PENLON LTD.ABINGDON SCIENCE PARK, ABINGDON Oxfordshire OX14 3NB GB2026

Registration numbers link to the FDA registration and listing record for that establishment.

FDA product codes

Recall records

Device recall records naming this company, most recent first
RecallProductReasonClassificationInitiatedStatus
Z-1653-2013Delta Vaporizer An anesthetic vaporizer is a device used to vaporize liquid anesthetic and deliver a controlled amount of the vapor to the patient.It has come to Penlon Ltd's attention of an instance where the installation and pre-use checks listed in the User Manual may not have been followed prior to the clinical use of the vaporizer. Penlon Ltd has updated the Installation and daily Pre-Use Check sections of the User Manual to ensure that the instructions are explicit and clear.Class IITerminated
Z-1318-2012Anesthesia Machines (digital display assembly); A gas machine for anesthesia is a device used to administer to a patient, continuously or intermittently, a general inhalation anesthetic and to maintain a patient's ventilation.Penlon, Ltd has identified the potential for the premature failure of a component in some Electronic Flowmeter sensor display unit PCB assemblies.Terminated
Z-1221-2012Crystal Metal Disposable Blades size Mac 4 (part number 50674, 50674/F, 50674/BMI) and Mac 3 (part numbers 50675, 50675/F, 50675/BMI) Product Usage: Disposable laryngoscope blades.Disposable laryngoscope blades incorrectly labeled with wrong size.Terminated
Z-3213-2011Crystal Metal Miller Disposable Blades (sizes 0 art no: 50676 and 00 part no 50647 Disposable laryngoscope bladesDisposable laryngoscope blades incorrectly labeled with wrong size.Terminated

Verification record

There is no verification record for this company. Most companies on this site have none: a record exists only where a company asked to be verified and MDM ran the checks, so the absence of one says nothing about the company.

Where there is a record, this is where it appears: what was checked, when it was checked, and the current status. An MDM Verified badge on another website links to a verify address on this domain that resolves to this section. A badge that does not resolve here is not ours.

What MDM checks, and what it does not

MDM coverage

MDM coverage of this company lists here, newest first. Submit news.

Is this your company?

This page is built from public FDA records. Company pages are free and factual, and stay free whether or not anyone claims them. Membership never changes editorial coverage or vetting outcomes.

Claiming lets Penlon, Ltd. edit what it says about itself and list the categories it works in. It grants no badge: claiming is not verification.

Claim this page

Data as of , FDA export datePage updated Source: openFDA, public domain