Skytron, LLC appears in FDA device records in Grand Rapids, MI. FDA records list 19 510(k) clearances between and , no PMA records and one registered establishment. As of , FDA records show 24 recalls for this company, and at least one establishment registration is current.

FDA records held for this company

510(k) clearances
19
PMA records
0
Recall records
24
Registered establishments
1

FDA records under these names

1 name

FDA records resolved to Skytron, LLC carry these names as well, as FDA wrote them. Each is the firm named on a registration, a 510(k), a PMA, a recall or an enforcement report that was joined to this company on a shared FDA identifier or on a matching name.

  • Skytron, Div. the Kmw Group, Inc.510(k), enforcement report, recall

510(k) clearance history

FDA records hold 19 510(k) clearances for Skytron, LLC between 1981 and 2007. The busiest year on record is 1985, with 4. The most recent is 2007, with 1.

Clearances by year, as a table
510(k) clearance decisions for Skytron, LLC, by decision year
YearClearances
19811
19854
19872
19903
19921
19931
19942
19951
19991
20001
20021
20071
510(k) clearances on record, most recent first
K numberDeviceProduct codeDecisionDecision date
K071698AURORA LED SERIES SURGICAL LIGHTSFSYSubstantially Equivalent
K021585STELLAR SERIES SURGICAL LIGHTS WITH HERMESFSYSubstantially Equivalent
K002463STELLARFSYSubstantially Equivalent
K992090MILLENNIUM GOLDFSYSubstantially Equivalent
K950192SKYTRON SKYBOOM SERIESFQOSubstantially Equivalent
K940616SKYTRON ELITE 3500 TABLEGDCSubstantially Equivalent
K933564SKYTRON EXAM LIGHTKZFSubstantially Equivalent
K926045SKYTRON LIFE ISLAND 21FNMSubstantially Equivalent
K915285SKYTRON INFINITY SERIES SURGICAL LIGHTSFSYSubstantially Equivalent
K900472SKYTRON MODEL 860 AND 800 COMP. SURGITA NEURO EQUIHBNSubstantially Equivalent
K900211SKYTRON UNIVERSE SERIES SURGICAL LIGHTSFSYSubstantially Equivalent
K900290SKYTRON MODEL 1100 AND MODEL 142JEASubstantially Equivalent
K873478SKYTRON MODEL 130 SURGICAL TABLEFWYSubstantially Equivalent
K870045SKYTRON MODEL 610-2INXSubstantially Equivalent
K853480SKYTRON ELITE 6000 & 6001 SURGICAL TABLESGDCSubstantially Equivalent
K853479SKYTRON ELITE 300 SURGERY TABLEFWWSubstantially Equivalent
K851830SKYTRON ELITE 7000 MICRO-SURGERY TABLEGDCSubstantially Equivalent
K851829SKYTRON ELITE 3100 SURGICAL TABLEGDCSubstantially Equivalent
K811311SKYTRON ELITE SURGICAL TABLESGBCSubstantially Equivalent

Registered establishments

FDA registered establishments for Skytron, LLC, with the product codes listed at each
RegistrationFEIEstablishmentAddressRegistration expiresProduct codes listed
18250141825014Skytron, LLC5085 Corporate Exchange Blvd SE, Grand Rapids, MI 49512 US2026and 14 more, listed in full below

Registration numbers link to the FDA registration and listing record for that establishment.

FDA product codes

Recall records

Device recall records naming this company, most recent first
RecallProductReasonClassificationInitiatedStatus
Z-2470-2023GS70H Salus Surgical Table, Product Code 18-071-70When the control of the operating table was used in Bluetooth mode, the operating table continued moving even after releasing the button on the control. Originally, the root cause was thought to be confined to Bluetooth/wireless communications between the control pendant and the surgical table. However, during investigation, Mizuho discovered that the failure could be replicated even in wired mode if communication between the pendant and table were somehow interrupted. The root cause appears to be: if communication between the controller and table is interrupted while a button is pressed, the table does not know if/when a button is released. This occurs in wireless or wired mode.Class IIOpen, Classified
Z-2469-2023GS70 Salus Surgical Table, Product Code 18-070-70When the control of the operating table was used in Bluetooth mode, the operating table continued moving even after releasing the button on the control. Originally, the root cause was thought to be confined to Bluetooth/wireless communications between the control pendant and the surgical table. However, during investigation, Mizuho discovered that the failure could be replicated even in wired mode if communication between the pendant and table were somehow interrupted. The root cause appears to be: if communication between the controller and table is interrupted while a button is pressed, the table does not know if/when a button is released. This occurs in wireless or wired mode.Class IIOpen, Classified
Z-1309-2022Product Name: GCX Channel Mounting Accessory Model/Catalog Number: H8-300-40-AUnder certain circumstances, the mounting screws may loosen or pull out from the attachment point on the Ergon 3 boom when the GCX Channel Mounting Accessory was used with the VST clamp as a monitor mount on the boom.Class IIOpen, Classified
Z-1861-2021Skyton Bracket Flatscreen, Revision 2 & 3-The FS32 is a single monitor mounting bracket intended for use with a 32 inch (maximum) flat screen monitor. Model: FS32Failure of the FS32 Monitor Brackets from the mounting block could potentially loosen over time and eventually detach from the baseplate, result in the display interface dismounting from its attachment point, causing injury to patients or staffClass IIOpen, Classified
Z-0071-2021VGDF-SKY (R4-010-06) VGA TO FIBER CONVERTER-Single Format Faceplate, a component of the SkyVision Linx 300 Integration Control System Model: VGDF-SKY (version 2). For communication and visual image management in the operating room suite.VGDF (VGA) Faceplate failure results in failure of video signal for SkyVision Linx 300, a secondary display. Video would continue on the primary source device displayClass IITerminated
Z-0109-2021SkyVision SDS System - Video Integration Model: GC-SDS-BSCB-200 - Product Usage: is a high quality, self-contained video switching and control unit for use in the operating room.Intermittent failure of a signal being sent to a monitor from the touch panel display causing the displaying monitor to go Blank and the touch panel to display a Blank image when reviewing the target display. If this issue were to happen during a case, cause increase risk to patient due to hospital losing the visual image.Class IITerminated
Z-1569-2020Skytron Ergon 3 Series Skyboom Monitor Bracket-Flatscreen Bracket, single monitor mount, 27" max. screen size Part number 3FCM1Potential for the weld to fail at the pivot point of the monitor bracket. This weld failure could cause the display interface and bracket to fall from its mounted location, resulting in injury.Class IIOpen, Classified
Z-1779-2019Skytron Integrity 270 Steam Sterilizer and Skytron Integrity 270VP Steam Product Usage: The SKYTRON Integrity 270 Steam Sterilizer for use in health care facilities. The Integrity Sterilizer incorporates high-pressure steam to sterilize nonporous or porous items and materials used in the health care industryWeld attaching the air heater assembly to the main sterilizer unit has shown signs of fatigue/failureClass IITerminated
Z-1844-2016EZ Slide Battery/line powered hydraulic table with removable leg section and 21 top slide General Purpose Surgical Table Skytron EZ Slide Operating Table General Purpose Surgical TableThe potential exists within the identified tables that incorrectly manufactured parts have been used in assembly. If a table is found to have these incorrectly manufactured parts, it is possible for the tables elevation column slide cap to become detached from the elevation column and could result in the loss of control of the table top and injury to the patient or staff.Class IITerminated
Z-1871-2016Ergon III Series Skyboom Monitor Bracket. Part # 3FCM1 Flatscreen Bracket, single monitor mount, 27inch max. screen sizePotential for the weld to fail at the pivot point of the monitor bracket. This weld failure could cause the display interface and bracket to fall from its mounted location, resulting in injury.Class IITerminated
Z-0655-2016Ergon 2 Articulating Equipment Boom Monitor Brackets mounting point for display interfaces utilized in clinical applications for viewing purposes and to provide an articulating point of movement on the ceiling mounted radial arm suspension system of the Ergon 2 equipment pendant / boomsThe hardware that holds the VESA plate and the display interface / monitor to the bracket may fail causing the display interface to fall from the bracket. Over time and with use the threaded rod hardware material can weaken and detach from the bracket. A display interface falling from its mounting location may result in injury to the patient or provider.Class IITerminated
Z-0534-2007Skytron Infinity Series surgical light with triple lightheads, 8 bulbs in 1 - 30' diameter lighthead and 5 bulbs in each of 2 - 22' diameter lightheads, Manufactured by Dai-ichi Shomei Co., Ltd., Made in Japan; Model IN302222EL, IF302222-B, IN30AR2222EL and IN30TV2222EL. (note only the 22'' lightheads are affected).If the mounting plug is improperly adjusted, the unit could separate, come apart, and fall from the mount.Terminated
Z-0533-2007Skytron Infinity Series surgical light with dual lightheads, 8 bulbs in 1 - 30' diameter lighthead and 5 bulbs in 1 - 22' diameter lighthead, Manufactured by Dai-ichi Shomei Co., Ltd., Made in Japan; Models IN3022EL and IF3022EL. (note only the 22'' lighthead is affected).If the mounting plug is improperly adjusted, the unit could separate, come apart, and fall from the mount.Terminated
Z-0532-2007Skytron Infinity Series surgical light with triple lightheads, 5 bulbs in each of 3 - 22' diameter lightheads, Manufactured by Dai-ichi Shomei Co., Ltd., Made in Japan; Models IF222222-B, IF222222EL and IN222222EL.If the mounting plug is improperly adjusted, the unit could separate, come apart, and fall from the mount.Terminated
Z-0531-2007Skytron Infinity Series surgical light with dual lightheads, 5 bulbs in 1 - 22' lighthead and 8 bulbs in 1 - 30' diameter lighthead, Manufactured by Dai-ichi Shomei Co., Ltd., Made in Japan; Model IF3022B. (note only the 22'' lighthead is affected.)If the mounting plug is improperly adjusted, the unit could separate, come apart, and fall from the mount.Terminated
Z-0530-2007Skytron Infinity Series surgical light with dual lightheads, 5 bulbs in each of 2 - 22' diameter lightheads, Manufactured by Dai-ichi Shomei Co., Ltd., Made in Japan; Models IF2222, IF2222-B, IF2222B/PT, IF2222EL and IN2222EL.If the mounting plug is improperly adjusted, the unit could separate, come apart, and fall from the mount.Terminated
Z-0529-2007Skytron Infinity Series surgical light, 5 bulbs in 1 - 22' diameter lighthead, Manufactured by Dai-ichi Shomei Co., Ltd., Made in Japan; Models IF22, IF22B, IF22LH, IF22LHH-B, IF22M-S, IN22, IN22EL, IN22LH and IF22(EL).If the mounting plug is improperly adjusted, the unit could separate, come apart, and fall from the mount.Terminated
Z-0528-2007Skytron Infinity Series surgical light with triple lightheads, 4 bulbs in each of 3 - 22' diameter lightheads, Manufactured by Dai-ichi Shomei Co., Ltd., Made in Japan; Models IF545454 and IF545454EL.If the mounting plug is improperly adjusted, the unit could separate, come apart, and fall from the mount.Terminated
Z-0527-2007Skytron Infinity Series surgical light with dual lightheads, 4 bulbs in each of 2 - 22' diameter lightheads, Manufactured by Dai-ichi Shomei Co., Ltd., Made in Japan; Models IF5454 and IF5454EL.If the mounting plug is improperly adjusted, the unit could separate, come apart, and fall from the mount.Terminated
Z-0526-2007Skytron Infinity Series surgical light, 4 bulbs in 1 - 22' diameter lighthead, Manufactured by Dai-ichi Shomei Co., Ltd., Made in Japan; Models IF54, IF54EL, IF54LH and IF54S.If the mounting plug is improperly adjusted, the unit could separate, come apart, and fall from the mount.Terminated
Z-0525-2007Skytron Infinity Series (also called Astro series) minor surgery light with dual lightheads, 3 bulbs in each of 2 - 19' diameter lightheads, Manufactured by Dai-ichi Shomei Co., Ltd., Made in Japan; Models IN1919 and IN1919EL and IN1919EL/PT.If the mounting plug is improperly adjusted, the unit could separate, come apart, and fall from the mount.Terminated
Z-0524-2007Skytron Infinity series (also called Astro series) minor surgery light, 3 bulbs in 1 - 19' diameter lighthead, Manufactured by Dai-ichi Shomei Co., Ltd., Japan; Models IN19, IN19EL, IN19LH and IN19S.If the mounting plug is improperly adjusted, the unit could separate, come apart, and fall from the mount.Terminated
Z-1497-06Skytron General Purpose Surgical Table, battery model; Model 6600B, Dist. by Skytron, Grand Rapids, MI.The release levers can inadvertently release under load while the leg section is positioned at a ninety degree angle causing the leg section to drop.Terminated
Z-1496-06Skytron General Purpose Surgical Table; Model 6600, Dist. by Skytron, Grand Rapids, MI.The release levers can inadvertently release under load while the leg section is positioned at a ninety degree angle causing the leg section to drop.Terminated

Verification record

There is no verification record for this company. Most companies on this site have none: a record exists only where a company asked to be verified and MDM ran the checks, so the absence of one says nothing about the company.

Where there is a record, this is where it appears: what was checked, when it was checked, and the current status. An MDM Verified badge on another website links to a verify address on this domain that resolves to this section. A badge that does not resolve here is not ours.

What MDM checks, and what it does not

MDM coverage

MDM coverage of this company lists here, newest first. Submit news.

Is this your company?

This page is built from public FDA records. Company pages are free and factual, and stay free whether or not anyone claims them. Membership never changes editorial coverage or vetting outcomes.

Claiming lets Skytron, LLC edit what it says about itself and list the categories it works in. It grants no badge: claiming is not verification.

Claim this page

Data as of , FDA export datePage updated Source: openFDA, public domain