Medical Device
Manufacturing
THE TRADE PAPER OF THE FACTORY FLOOR

Change Healthcare Canada Company

RICHMOND British Columbia, CA

CHANGE HEALTHCARE CANADA COMPANY appears in FDA device records in RICHMOND British Columbia, CA. FDA records list 6 510(k) clearances between and , no PMA records and one registered establishment. As of , FDA records show 20 recalls for this company, and at least one establishment registration is current.

FDA records held for this company

510(k) clearances
6
PMA records
0
Recall records
20
Registered establishments
1

FDA records under these names

3 names

FDA records resolved to Change Healthcare Canada Company carry these names as well, as FDA wrote them. Each is the firm named on a registration, a 510(k), a PMA, a recall or an enforcement report that was joined to this company on a shared FDA identifier or on a matching name.

  • Mckesson Medical Imaging Company510(k), enforcement report, recall
  • Mckesson Medical Imaging Groupenforcement report, recall
  • Mckesson Medical Immagingenforcement report, recall

510(k) clearance history

FDA records hold 6 510(k) clearances for Change Healthcare Canada Company between 2005 and 2024. The busiest year on record is 2005, with 1. The most recent is 2024, with 1.

Clearances by year, as a table
510(k) clearance decisions for Change Healthcare Canada Company, by decision year
YearClearances
20051
20141
20151
20181
20211
20241
510(k) clearances on record, most recent first
K numberDeviceProduct codeDecisionDecision date
K241981Change Healthcare Stratus Imaging PACSLLZSubstantially Equivalent
K210719Change Healthcare Anatomical AIQIHSubstantially Equivalent
K181185Change Healthcare Enterprise ViewerLLZSubstantially Equivalent
K142850McKesson Radiology Mammography PlusLLZSubstantially Equivalent
K140909MCKESSON RADIOLOGYLLZSubstantially Equivalent
K043146HORIZON MEDICAL IMAGINGLLZSubstantially Equivalent

Registered establishments

FDA registered establishments for Change Healthcare Canada Company, with the product codes listed at each
RegistrationFEIEstablishmentAddressRegistration expiresProduct codes listed
80222573003757840CHANGE HEALTHCARE CANADA COMPANY10711 CAMBIE ROAD, RICHMOND British Columbia V6X 3G5 CA2026and 20 more, listed in full below

Registration numbers link to the FDA registration and listing record for that establishment.

FDA product codes

Recall records

Device recall records naming this company, most recent first
RecallProductReasonClassificationInitiatedStatus
Z-0030-2026Change Healthcare Radiology Solutions software version 14.2.2Due to software issue, radiology reports may not be fully displayed when viewing.Class IIOpen, Classified
Z-2072-2025Change Healthcare Cardiology Hemodynamics SoftwareDue to complaints, software update may cause software to unexpectedly shutdown.Class IIOpen, Classified
Z-2071-2025Change Healthcare Cardiology Hemo SoftwareDue to complaints, software update may cause software to unexpectedly shutdown.Class IIOpen, Classified
Z-0128-2025McKesson Cardiology Hemo. Versions 13.0, 13.1.1, 13.1.2, 13.2, 13.2.1, 14.0.A potential issue has been identified in Change Healthcare Cardiology Hemo where incorrect data entry can lead to inaccurate hemodynamic calculations, potentially resulting in misdiagnosis and inappropriate treatment. This issue occurs when the unit of measurement (UOM) for hemoglobin is configured in a way that differs from the users understanding.Class IIOpen, Classified
Z-0127-2025Horizon Cardiology Hemo. Version 12.2.A potential issue has been identified in Change Healthcare Cardiology Hemo where incorrect data entry can lead to inaccurate hemodynamic calculations, potentially resulting in misdiagnosis and inappropriate treatment. This issue occurs when the unit of measurement (UOM) for hemoglobin is configured in a way that differs from the users understanding.Class IIOpen, Classified
Z-0126-2025Change Healthcare Cardiology Hemo. Versions 14.2, 14.1.1, 14.2, 14.3, 14.3.2, 14.3, 15.0.1, 15.1.A potential issue has been identified in Change Healthcare Cardiology Hemo where incorrect data entry can lead to inaccurate hemodynamic calculations, potentially resulting in misdiagnosis and inappropriate treatment. This issue occurs when the unit of measurement (UOM) for hemoglobin is configured in a way that differs from the users understanding.Class IIOpen, Classified
Z-0551-2024Change Healthcare Stratus Imaging PACS 1.4 and Stratus Imaging Share 1.4, a component of Stratus Imaging PACS.Under certain circumstances, information from HL7 messages received by Stratus PACS/Imaging Share systems has been incorrectly associated with another patient's study.Class IIOpen, Classified
Z-0237-2024Change Healthcare Radiology Solutions, software versions 14.0, 14.1, and 14.2 Medical image and information management software.Change Healthcare has identified a software issue where Change Healthcare Radiology Solutions 14.0, 14.1, and 14.2 may not update records in external applications.Class IIOpen, Classified
Z-1773-2021Change Healthcare Enterprise Viewer - Product Usage: intended to be used with off-the-shelf hardware for the 2D and 3D display of DICOM and non-DICOM medical images, reports, and multimedia content.A software defect was identified where the Image Styles defined by presentation states from CHRS are not displayed in CHEV.Class IIOpen, Classified
Z-1508-2021Change Healthcare Enterprise ViewerChange Healthcare has identified an intermittent software defect which may result in an anchor study failing to display.Class IIOpen, Classified
Z-0072-2021Change Healthcare Radiology Solutions 14.0Software defect which may potentially result in one or more images missing in a studyClass IITerminated
Z-1682-2020McKesson Cardiology ECG Management, Change Healthcare Cardiology ECG ManagementInaccurate estimation of the heart rate may occur in instances where the user is estimating heart rate counting grid squares using the Sequential ECG formatClass IIOpen, Classified
Z-1396-2017McKesson Radiology 12.2 - Picture Archive Communication System (PACS)Issue for customers that use an EMR login or legacy web URL login or legacy web URL login for McKesson Radiology PACS that may result in missing images in a newly imported study, and/or study imports that remain in an "in-progress" status.Class IITerminated
Z-2872-2016McKesson Radiology, versions 12.1.1 and 12.2 McKesson Radiology (MR) is a Picture Archiving Communication System (PACS). It is a medical image and information management application that is intended to receive, transmit, store, retrieve, display, print and process digital medical images, digital medical video, and associated medical information from various medical imaging systems.The STAT priority icon was not displayed in the Study List when the study was opened.Class IITerminated
Z-1182-2016McKesson Horizon Medical Imaging (HMI) products versions 4.6.1 to including 11.9 and McKesson Radiology (MR) products 12.0 and 12.1.1.McKesson has identified a design deficiency where under rare circumstances, imported images/studies may re-use a non-unique image directory. This issue may cause incorrect images to be displayed for a patient.Class IITerminated
Z-1728-2014Horizon Medical Imaging Horizon Medical Imaging is a medical image and information management application that is intended to receive transmit, store, retrieve, display, print and process digital medical images, digital medical video, and associated medical information from various medical imaging systems.Firm received a complaint that an unreported study performed that day could not be opened from the archive.Class IITerminated
Z-2121-2014Horizon Medical Imaging It is a medical image and information management application that is intended to receive, transmit, store, retrieve, display print and process digital medical images, digital medical video, and associated medical information from various medical imaging systems.The firm has identified a software issue which may cause a discrepancy between the index of images expected by the application, and the actual content of the folder storing the images.Class IITerminated
Z-1617-2014McKesson Radiology-PACS. McKesson Radiology is a medical image and information application that is intended to receive, transmit, store, retrieve, display, print and process digital medical images, digital medical video, and associated medical information from various medical imaging systems.High priority alert icon was not displayed in the Study List when there are no Stat studies present. However, the High priority alert icon is visible when studies marked as Stat priority exist in the Study List.Class IITerminated
Z-2238-2012Horizon Medical Imaging system. Product Usage: Horizon Medical Imaging is a medical image and information management application that is intended to receive, transmit store, retrieve, display, print and process digital medical images, digital medical video, and associated medical information from various medical image systems. The medical modalities of these medical imaging systems include, but are not limited to, all modalities supported by ACR/NEMA DICOM 3.0 (specifically including mammographic images). Horizon Medical Imaging is intended to function with a variety of storage systems and printers via DICOM and other computer industry standard interfaces and protocols. Horizon Medical Imaging is indicated for use by trained medical professionals including, but not limited to, radiologist, physicians, and medical technologists. Horizon Medical Imaging is also indicated for use in soft copy diagnostic interpretation of medical images and video by physicians trained in such practice (specifically including soft copy diagnostic interpretation of mammographic images).There is a potential to save reports in RadReport with an Incorrect Final Status.Class IITerminated
Z-1735-2010Voiceware clip software update to certain Horizon Medical Imaging Systems. McKesson Medical Imaging Company. Richmond, Canada V6X 3G5. Intended to receive, transmit, store, retrieve, display, print and process digital medical images, digital medical video and associated medical information from various medical imaging systems.Voice Clip issue: When the user is recording voice clips in Horizon Rad Station, there is a potential for voice clips to be saved to the incorrect study of the same patient.Terminated

Verification record

There is no verification record for this company. Most companies on this site have none: a record exists only where a company asked to be verified and MDM ran the checks, so the absence of one says nothing about the company.

Where there is a record, this is where it appears: what was checked, when it was checked, and the current status. An MDM Verified badge on another website links to a verify address on this domain that resolves to this section. A badge that does not resolve here is not ours.

What MDM checks, and what it does not

MDM coverage

MDM coverage of this company lists here, newest first. Submit news.

Is this your company?

This page is built from public FDA records. Company pages are free and factual, and stay free whether or not anyone claims them. Membership never changes editorial coverage or vetting outcomes.

Claiming lets Change Healthcare Canada Company edit what it says about itself and list the categories it works in. It grants no badge: claiming is not verification.

Claim this page

Data as of , FDA export datePage updated Source: openFDA, public domain